The Original ExoQuick
- Saves time and labor
- Is easily scalable
- Conserves precious sample
- Delivers high yields of functional, high quality exosomes
- Can be used to isolate exosomes for a wide range of downstream applications, including biomarker studies, exosomal miRNA profiling, exosomal proteomics, exosomal lipidomics/metabolomics, functional studies, such as in cell-to-cell signaling, and basic biology, such as roles in tumorigenesis.
Products
Catalog Number | Description | Size | Price | Quantity | Add to Cart | |||
---|---|---|---|---|---|---|---|---|
EXOQ20A-1 | ExoQuick exosome precipitation solution | 20 mL | $1146 |
|
||||
EXOQ5A-1 | ExoQuick exosome precipitation solution | 5 mL | $355 |
|
Overview
Overview
A better way to isolate exosomes
"We therefore pursued the ExoQuick® method for further study, as these samples required much less sample input, a key benefit when working with clinical samples and mouse models1."
Need exosomes? SBI's ExoQuick, original formulation, enables high-throughput, quantitative isolation of exosomes from low volumes (as little as 100 µl) of serum, plasma, or ascites fluid. Compatible with a wide variety of downstream applications, ExoQuick is an effective and proven alternative to ultracentrifugation1-3.
ExoQuick’s fast, ultracentrifugation-free method:- Saves time and labor
- Is easily scalable
- Conserves precious sample
- Delivers high yields of functional, high quality exosomes
- Can be used to isolate exosomes for a wide range of downstream applications, including biomarker studies, exosomal miRNA profiling, exosomal proteomics, exosomal lipidomics/metabolomics, functional studies, such as in cell-to-cell signaling, basic biology, such as role in tumorigenesis.
Biofluid | Sample volume | ExoQuick Volume |
---|---|---|
Serum, plasma, and ascites fluid. | 250 μl | 63 μl |
In electron microscopy studies, exosomes isolated with ExoQuick appear similar to exosomes isolated using ultracentrifugation1-2, and these exosomes are also active in numerous functional assays1-3.
Exosomes isolated with ExoQuick can be used for all types of protein profiling and protein characterization studies, such as mass spectrometry, Western blotting, ELISA, and more. Higher protein yields are achieved by ExoQuick purification than by chromatography, DynaBeads, or ultracentrifugation.
Exosomes isolated with ExoQuick also provide excellent samples for studying exosome-associated nucleic acids such as microRNAs, siRNAs, and even mRNA. Quantitative analytical techniques such as qPCR, microarray studies, and next-generation sequencing are all compatible with nucleic acids isolated from ExoQuick-purified exosomes.
Backed by a growing number of publications, ExoQuick is often the best option for researchers working with low sample volumes, such as clinical research samples or small animal models.
ExoQuick exosome isolation methods are patented technologies4.
Choose the right ExoQuick for your application:Application | Product | Catalog # |
---|---|---|
Purest EV isolation | ExoQuick ULTRA and ExoQuick-TC ULTRA | EQULTRA-20A-1 EQULTRA-20TC-1 |
General purpose EV isolation | ExoQuick and ExoQuick-TC | EXOQ20A-1 EXOTC50A-1 |
EV isolation for pre-clinical/in vivo studies | ExoQuick-CG | EXOCG50A-1 |
EV isolation that removes contaminating lipoprotein particles from plasma or serum | ExoQuick-LP | EXOLP5A-1 |
EV isolation that includes a de-fibrinating plasma step prior to isolation | ExoQuick Plasma Prep with Thrombin | EXOQ5TM-1 |
- Chugh PE, et al. Systemically Circulating Viral and Tumor-Derived MicroRNAs in KSHV-Associated Malignancies. PLoS Pathog. 2013. 9(7): e1003484. PMCID: PMC3715412.
- Umezu T, et al. Leukemia cell to endothelial cell communication via exosomal miRNAs. Oncogene. 2013 May 30. 32(22):2747-55. PMID: 22797057.
- Sohel MM, et al. Exosomal and Non-Exosomal Transport of Extra-Cellular microRNAs in Follicular Fluid: Implications for Bovine Oocyte Developmental Competence. PLoS One. 2013 Nov 4. 8(11):e78505. PMCID: PMC3817212.
- Antes T, et al. Methods for Microvesicle Isolation and Selective Removal. Patent No.: US 9,005,888 B2.
References
How It Works
https://www.systembio.com/anti-cd63-antibody-with-goat-anti-rabbit-hrp-secondary-antibodyHow It Works
High-throughput, quantitative exosome recovery
ExoQuick can be used to purify exosomes from plasma1, serum2, and malignant ascites3. With a simple workflow involving minimal hands-on time and low input sample volume requirements, ExoQuick is an excellent option for researchers who need to purify multiple exosome samples and/or samples from small animal models or clinical research samples.
To isolate exosomes from cleared serum, plasma, or ascites fluid, simply:
- Add an appropriate volume of ExoQuick to as little as 100 µl sample
- Incubate for at least one hour at 4°C
- Isolate exosomes with a 30-minute low-speed spin (1500 g).
Isolated exosomes can be found in the pellet and resuspended in an appropriate solution.
You can verify the presence of exosomes with a number of different methods, including Western blotting for general exosome markers (CD63, CD9, CD81, and HSP70), NanoSight analysis, or EM (learn about different ways to detect exosomes and more in our Exosome Basics Guide).
The Bottom Line
With ExoQuick, you can obtain high-quality exosomes from most biofluids using a protocol that can easily be performed on multiple samples and requires very low volumes of input sample.
REFERENCES
- Chugh PE, et al. Systemically Circulating Viral and Tumor-Derived MicroRNAs in KSHV-Associated Malignancies. PLoS Pathog. 2013. 9(7): e1003484. PMCID: PMC3715412.
- Epple LM, et al. Medulloblastoma Exosome Proteomics Yield Functional Roles for Extracellular Vesicles. PLoS ONE. 2012. 7(7): e42064. PMCID: PMC3407172.
- As featured in: Exosome Isolation for Proteomic Analyses and RNA Profiling Douglas D. Taylor, Wolfgang Zacharias and Cicek Gercel-Taylor, Serum/Plasma Proteomics, Methods in Molecular Biology, 2011, Volume 728, Part 4, 235-246.
Supporting Data
Supporting Data
Use ExoQuick to isolate exosomes for proteomics and miRNA profiling studies
ExoQuick helps researchers discover protein and RNA biomarkers as well as study exosome biology by enabling fast and quantitative isolation of exosomes.
ExoQuick supports exosomal protein analysis from ascites
Exosomes were isolated from ovarian tumor ascites fluid using ExoQuick, chromatography, DynaBeads, or ultracentrifugation. The ExoQuick method consistently delivered higher concentrations of protein than the other three isolation methods used (Figure 1).
ExoQuick supports high exosomal miRNA yields
With ExoQuick, you can quickly and easily isolate high quality exosomes for miRNA analysis (Figure 2).
Exosomal microRNAs were recovered from ovarian tumor ascites fluid using either ExoQuick isolation of exosomes followed by Trizol extraction of RNA, Trizol extraction of ovarian tumor ascites fluid with no exosome isolation, or exosome purification using DynaBeads followed by Trizol extraction of RNA. The samples where exosomes were purified using ExoQuick showed the highest yields of microRNAs (Figure 2).
Characterizing ExoQuick exosomes with NanoSight
Exosomes purified with ExoQuick from serum show the expected particle size distribution and high concentration yields when analyzed using NanoSight’s Nanoparticle Tracking Analysis (NTA, Figure 3).
FAQs
If you need more information or want to speak to a specialist, you can contact the company at 1-(866) 417-9257 or visit our website.
Resources
Citations
Related Products
Products
Catalog Number | Description | Size | Price | Quantity | Add to Cart | |||
---|---|---|---|---|---|---|---|---|
EXOQ20A-1 | ExoQuick exosome precipitation solution | 20 mL | $1146 |
|
||||
EXOQ5A-1 | ExoQuick exosome precipitation solution | 5 mL | $355 |
|
Overview
Overview
A better way to isolate exosomes
"We therefore pursued the ExoQuick® method for further study, as these samples required much less sample input, a key benefit when working with clinical samples and mouse models1."
Need exosomes? SBI's ExoQuick, original formulation, enables high-throughput, quantitative isolation of exosomes from low volumes (as little as 100 µl) of serum, plasma, or ascites fluid. Compatible with a wide variety of downstream applications, ExoQuick is an effective and proven alternative to ultracentrifugation1-3.
ExoQuick’s fast, ultracentrifugation-free method:- Saves time and labor
- Is easily scalable
- Conserves precious sample
- Delivers high yields of functional, high quality exosomes
- Can be used to isolate exosomes for a wide range of downstream applications, including biomarker studies, exosomal miRNA profiling, exosomal proteomics, exosomal lipidomics/metabolomics, functional studies, such as in cell-to-cell signaling, basic biology, such as role in tumorigenesis.
Biofluid | Sample volume | ExoQuick Volume |
---|---|---|
Serum, plasma, and ascites fluid. | 250 μl | 63 μl |
In electron microscopy studies, exosomes isolated with ExoQuick appear similar to exosomes isolated using ultracentrifugation1-2, and these exosomes are also active in numerous functional assays1-3.
Exosomes isolated with ExoQuick can be used for all types of protein profiling and protein characterization studies, such as mass spectrometry, Western blotting, ELISA, and more. Higher protein yields are achieved by ExoQuick purification than by chromatography, DynaBeads, or ultracentrifugation.
Exosomes isolated with ExoQuick also provide excellent samples for studying exosome-associated nucleic acids such as microRNAs, siRNAs, and even mRNA. Quantitative analytical techniques such as qPCR, microarray studies, and next-generation sequencing are all compatible with nucleic acids isolated from ExoQuick-purified exosomes.
Backed by a growing number of publications, ExoQuick is often the best option for researchers working with low sample volumes, such as clinical research samples or small animal models.
ExoQuick exosome isolation methods are patented technologies4.
Choose the right ExoQuick for your application:Application | Product | Catalog # |
---|---|---|
Purest EV isolation | ExoQuick ULTRA and ExoQuick-TC ULTRA | EQULTRA-20A-1 EQULTRA-20TC-1 |
General purpose EV isolation | ExoQuick and ExoQuick-TC | EXOQ20A-1 EXOTC50A-1 |
EV isolation for pre-clinical/in vivo studies | ExoQuick-CG | EXOCG50A-1 |
EV isolation that removes contaminating lipoprotein particles from plasma or serum | ExoQuick-LP | EXOLP5A-1 |
EV isolation that includes a de-fibrinating plasma step prior to isolation | ExoQuick Plasma Prep with Thrombin | EXOQ5TM-1 |
- Chugh PE, et al. Systemically Circulating Viral and Tumor-Derived MicroRNAs in KSHV-Associated Malignancies. PLoS Pathog. 2013. 9(7): e1003484. PMCID: PMC3715412.
- Umezu T, et al. Leukemia cell to endothelial cell communication via exosomal miRNAs. Oncogene. 2013 May 30. 32(22):2747-55. PMID: 22797057.
- Sohel MM, et al. Exosomal and Non-Exosomal Transport of Extra-Cellular microRNAs in Follicular Fluid: Implications for Bovine Oocyte Developmental Competence. PLoS One. 2013 Nov 4. 8(11):e78505. PMCID: PMC3817212.
- Antes T, et al. Methods for Microvesicle Isolation and Selective Removal. Patent No.: US 9,005,888 B2.
References
How It Works
https://www.systembio.com/anti-cd63-antibody-with-goat-anti-rabbit-hrp-secondary-antibodyHow It Works
High-throughput, quantitative exosome recovery
ExoQuick can be used to purify exosomes from plasma1, serum2, and malignant ascites3. With a simple workflow involving minimal hands-on time and low input sample volume requirements, ExoQuick is an excellent option for researchers who need to purify multiple exosome samples and/or samples from small animal models or clinical research samples.
To isolate exosomes from cleared serum, plasma, or ascites fluid, simply:
- Add an appropriate volume of ExoQuick to as little as 100 µl sample
- Incubate for at least one hour at 4°C
- Isolate exosomes with a 30-minute low-speed spin (1500 g).
Isolated exosomes can be found in the pellet and resuspended in an appropriate solution.
You can verify the presence of exosomes with a number of different methods, including Western blotting for general exosome markers (CD63, CD9, CD81, and HSP70), NanoSight analysis, or EM (learn about different ways to detect exosomes and more in our Exosome Basics Guide).
The Bottom Line
With ExoQuick, you can obtain high-quality exosomes from most biofluids using a protocol that can easily be performed on multiple samples and requires very low volumes of input sample.
REFERENCES
- Chugh PE, et al. Systemically Circulating Viral and Tumor-Derived MicroRNAs in KSHV-Associated Malignancies. PLoS Pathog. 2013. 9(7): e1003484. PMCID: PMC3715412.
- Epple LM, et al. Medulloblastoma Exosome Proteomics Yield Functional Roles for Extracellular Vesicles. PLoS ONE. 2012. 7(7): e42064. PMCID: PMC3407172.
- As featured in: Exosome Isolation for Proteomic Analyses and RNA Profiling Douglas D. Taylor, Wolfgang Zacharias and Cicek Gercel-Taylor, Serum/Plasma Proteomics, Methods in Molecular Biology, 2011, Volume 728, Part 4, 235-246.
Supporting Data
Supporting Data
Use ExoQuick to isolate exosomes for proteomics and miRNA profiling studies
ExoQuick helps researchers discover protein and RNA biomarkers as well as study exosome biology by enabling fast and quantitative isolation of exosomes.
ExoQuick supports exosomal protein analysis from ascites
Exosomes were isolated from ovarian tumor ascites fluid using ExoQuick, chromatography, DynaBeads, or ultracentrifugation. The ExoQuick method consistently delivered higher concentrations of protein than the other three isolation methods used (Figure 1).
ExoQuick supports high exosomal miRNA yields
With ExoQuick, you can quickly and easily isolate high quality exosomes for miRNA analysis (Figure 2).
Exosomal microRNAs were recovered from ovarian tumor ascites fluid using either ExoQuick isolation of exosomes followed by Trizol extraction of RNA, Trizol extraction of ovarian tumor ascites fluid with no exosome isolation, or exosome purification using DynaBeads followed by Trizol extraction of RNA. The samples where exosomes were purified using ExoQuick showed the highest yields of microRNAs (Figure 2).
Characterizing ExoQuick exosomes with NanoSight
Exosomes purified with ExoQuick from serum show the expected particle size distribution and high concentration yields when analyzed using NanoSight’s Nanoparticle Tracking Analysis (NTA, Figure 3).
FAQs
If you need more information or want to speak to a specialist, you can contact the company at 1-(866) 417-9257 or visit our website.