ExoGlow™-NTA Fluorescent Labeling Kit (for Particle Metrix ZetaView®)
- The only commercially available kit that specifically labels EVs for fluorescent NTA quantitation
- Delivers high signal-to-noise ratio with a proprietary dye that specifically detects EVs
- Validated using common EV isolation methods including as ExoQuick™, ultracentrifugation, and column-based methods (see Supporting Data, Figure 1)
- Optimized for a fast protocol that takes only 20 minutes from isolated sample to analysis
Products
Catalog Number | Description | Size | Price | Quantity | Add to Cart | |||
---|---|---|---|---|---|---|---|---|
EXONTA110A-1 | ExoGlow™-NTA Fluorescent Labeling Kit (for Particle Metrix ZetaView®) | 10 Reactions | $424 |
|
Overview
Overview
Only detect extracellular vesicles with Nanoparticle Tracking Analysis (NTA) Building upon ExoGlow-NTA, a proprietary dye that enables fluorescent NTA analysis of only the extracellular vesicles present in a heterogenous sample, SBI has developed a new version compatible with Particle Metrix's ZetaView® instrument. The new ExoGlow-NTA Fluorescent Labeling Kit (for Particle Metrix ZetaView) provides accurate EV NTA data that excludes protein aggregates, membrane fractions, and other background particles to provide EV-specific particle size and concentration.- The only commercially available kit that specifically labels EVs for fluorescent NTA quantitation
- Delivers high signal-to-noise ratio with a proprietary dye that specifically detects EVs
- Validated using common EV isolation methods including as ExoQuick™, ultracentrifugation, and column-based methods (see Supporting Data, Figure 1)
- Optimized for a fast protocol that takes only 20 minutes from isolated sample to analysis
References
How It Works
How It Works
Gain more accurate insight into your exosome sample
The new ExoGlow-NTA Fluorescent Labeling Kit (for Particle Metrix ZetaView) takes advantage of the fluorescence capabilities of the ZetaView NTA instrument with a proprietary fluorescent dye, which works by reacting specifically and efficiently to the surface of intact vesicles. Membrane fragments, protein aggregates, and other background particles do not activate the ExoGlow-NTA dye, resulting in exclusion of these species from fluorescent NTA analysis (Figure 1). Thus, with the ExoGlow-NTA Kit, the data delivered by ZetaView more accurately represents the EV populations in your sample rather than all particles, as is typically reported by conventional (non-fluorescent) NTA.
The ExoGlow-NTA Fluorescent Labeling Kit comes with three components: 1) Labeling dye 2) Standard and 3) Reaction Buffer. Simply mix the dye with the reaction buffer, add 1-100 µg of EVs (or protein equivalent), incubate for 5 minutes, and you are ready for fluorescent NTA analysis. The provided Internal Standards are size-controlled synthetic liposomes that provide a positive control for NTA calibration as well as EV/exosome labeling efficiency using the ExoGlow-NTA Kit.
Don’t have access to an NTA instrument? SBI also offers fluorescent NTA as a service. Simply send us your samples, and we will isolate, label, and perform fluorescent NTA on your EVs. Email our Services department to request a quote now.
Supporting Data
Supporting Data
Better NTA data on exosomes using ExoGlow-NTA
SBI’s ExoGlow-NTA Fluorescent Labeling Kit delivers highly accurate EV quantitation in a quick and easy workflow. The proprietary dye offers highly efficient labeling (Figure 2), very low background (Figure 3), and is compatible with a wide range of EV isolation techniques (Figure 4).
FAQs
Resources
Citations
Related Products
Products
Catalog Number | Description | Size | Price | Quantity | Add to Cart | |||
---|---|---|---|---|---|---|---|---|
EXONTA110A-1 | ExoGlow™-NTA Fluorescent Labeling Kit (for Particle Metrix ZetaView®) | 10 Reactions | $424 |
|
Overview
Overview
Only detect extracellular vesicles with Nanoparticle Tracking Analysis (NTA) Building upon ExoGlow-NTA, a proprietary dye that enables fluorescent NTA analysis of only the extracellular vesicles present in a heterogenous sample, SBI has developed a new version compatible with Particle Metrix's ZetaView® instrument. The new ExoGlow-NTA Fluorescent Labeling Kit (for Particle Metrix ZetaView) provides accurate EV NTA data that excludes protein aggregates, membrane fractions, and other background particles to provide EV-specific particle size and concentration.- The only commercially available kit that specifically labels EVs for fluorescent NTA quantitation
- Delivers high signal-to-noise ratio with a proprietary dye that specifically detects EVs
- Validated using common EV isolation methods including as ExoQuick™, ultracentrifugation, and column-based methods (see Supporting Data, Figure 1)
- Optimized for a fast protocol that takes only 20 minutes from isolated sample to analysis
References
How It Works
How It Works
Gain more accurate insight into your exosome sample
The new ExoGlow-NTA Fluorescent Labeling Kit (for Particle Metrix ZetaView) takes advantage of the fluorescence capabilities of the ZetaView NTA instrument with a proprietary fluorescent dye, which works by reacting specifically and efficiently to the surface of intact vesicles. Membrane fragments, protein aggregates, and other background particles do not activate the ExoGlow-NTA dye, resulting in exclusion of these species from fluorescent NTA analysis (Figure 1). Thus, with the ExoGlow-NTA Kit, the data delivered by ZetaView more accurately represents the EV populations in your sample rather than all particles, as is typically reported by conventional (non-fluorescent) NTA.
The ExoGlow-NTA Fluorescent Labeling Kit comes with three components: 1) Labeling dye 2) Standard and 3) Reaction Buffer. Simply mix the dye with the reaction buffer, add 1-100 µg of EVs (or protein equivalent), incubate for 5 minutes, and you are ready for fluorescent NTA analysis. The provided Internal Standards are size-controlled synthetic liposomes that provide a positive control for NTA calibration as well as EV/exosome labeling efficiency using the ExoGlow-NTA Kit.
Don’t have access to an NTA instrument? SBI also offers fluorescent NTA as a service. Simply send us your samples, and we will isolate, label, and perform fluorescent NTA on your EVs. Email our Services department to request a quote now.
Supporting Data
Supporting Data
Better NTA data on exosomes using ExoGlow-NTA
SBI’s ExoGlow-NTA Fluorescent Labeling Kit delivers highly accurate EV quantitation in a quick and easy workflow. The proprietary dye offers highly efficient labeling (Figure 2), very low background (Figure 3), and is compatible with a wide range of EV isolation techniques (Figure 4).