ExoQuick-TC PLUS
- Better—delivers as much as 150-fold higher yields than ultracentrifugation-based methods
- Cleaner—dramatically reduces the amount of carry-over protein compared to other column- or precipitation-based kits, and even ultracentrifugation-based methods
- Powerful—detects biomarkers with as much as a 3-fold increase in sensitivity
- Fast—takes less than 10 minutes of hands-on-time after initial ExoQuick isolation
Products
Catalog Number | Description | Size | Price | Quantity | Add to Cart | |||
---|---|---|---|---|---|---|---|---|
EQPL10TC-1 | ExoQuick-TC PLUS Exosome Purification Kit - Tissue Culture Media | 10 Reactions | $537 |
|
Overview
Overview
We have recently released our most advanced EV isolation system to-date—ExoQuick-TC ULTRA—unmatched combination of yield, purity, ease of use, and cost. Learn more.
Quick and efficient exosome isolation for sensitive applications
While the ExoQuick® family of reagents speed-up and simplify exosome isolation and are compatible with most downstream uses, some applications are especially sensitive to carry-over of non-exosomal proteins—applications such as mass spectrometry, Western blotting of low abundance markers, exosome labeling, and in vivo/ex vivo exosome delivery. Which is why SBI offers ExoQuick PLUS.
Less is more—ExoQuick PLUS and ExoQuick-TC PLUS for when you need an extra level of confidence:
- Better—delivers as much as 150-fold higher yields than ultracentrifugation-based methods
- Cleaner—dramatically reduces the amount of carry-over protein compared to other column- or precipitation-based kits, and even ultracentrifugation-based methods
- Powerful—detects biomarkers with as much as a 3-fold increase in sensitivity
- Fast—takes less than 10 minutes of hands-on-time after initial ExoQuick isolation
Building on our popular ExoQuick family of products, ExoQuick-TC PLUS delivers dramatically reduced albumin contamination in serum/plasma preparations compared to ultracentrifugation-based isolation methods, and considerably less carryover protein compared to other exosome isolation kits. Even better, isolation with the ExoQuick PLUS family of products results in much higher yields than isolation with ultracentrifugation—as much as 150-fold higher.
With a simple treatment of our ready-to-use, customized ExoQuick PLUS Microspheres (kits contain enough ExoQuick-TC and pre-packed Microspheres for 10 reactions*), you can obtain highly pure, intact exosomes suitable for a variety of protein-sensitive applications. Total hands-on time after ExoQuick-TC isolation is less than 10 minutes!
*For exosome isolation from serum or plasma, one reaction is defined as 250 µL of serum or plasma. For exosome isolation from tissue culture media, one reaction is defined as 5 mL of media.
Learn more about ExoQuick—click here.
Choose the right ExoQuick for your application:
Application | Product | Catalog # |
---|---|---|
Purest EV isolation | ExoQuick ULTRA and ExoQuick-TC ULTRA | EQULTRA-20A-1 EQULTRA-20TC-1 |
General purpose EV isolation | ExoQuick and ExoQuick-TC | EXOQ20A-1 EXOTC50A-1 |
EV isolation for pre-clinical/in vivo studies | ExoQuick-CG | EXOCG50A-1 |
EV isolation that removes contaminating lipoprotein particles from plasma or serum | ExoQuick-LP | EXOLP5A-1 |
EV isolation that includes a de-fibrinating plasma step prior to isolation | ExoQuick Plasma Prep with Thrombin | EXOQ5TM-1 |
References
How It Works
How It Works
High-throughput, quantitative exosome recovery
ExoQuick-TC PLUS can be used to purify exosomes from tissue culture media1, plus several biofluids, including saliva2, urine3, follicular fluid4, and breast milk5. With a simple workflow involving minimal hands-on time and low input sample volume requirements, ExoQuick-TC PLUS is an excellent option for researchers who need to purify multiple exosome samples and/or samples from small animal models or clinical research samples that will then be used in sensitive downstream applications.
To isolate exosomes from cell culture media, simply:
- Add an appropriate volume of ExoQuick-TC PLUS to as little as 100 µl sample
- Incubate for at least one hour at 4°C
- Pellet exosomes with a 30-minute low-speed spin (1500g)
- Resuspend pellet, add ExoQuick PLUS Microspheres, and incubate for 10 minutes at 4°C
- Remove microspheres with a 30-minute low-speed spin (1500g)
ExoQuick-TC PLUS-isolated exosomes can be found in the supernatant.
You can verify the presence of exosomes with a number of different methods, including Western blotting for general exosome markers (CD63, CD9, CD81, and HSP70), Nanoparticle Tracking Analysis (NTA), or EM (learn about different ways to detect exosomes and more in our Exosome Basics Guide).
REFERENCES
- Zhu L, et al. Novel method for extracting exosomes of hepatocellular carcinoma cells. World J Gastroenterol. 2014 June 7. 20(21): 6651-6657. PMCID: PMC4047354.
- Yang J, et al. Detection of Tumor Cell-Specific mRNA and Protein in Exosome-Like Microvesicles from Blood and Saliva. PLoS ONE. 2014. 9(11): e110641. PMCID: PMC 4232306.
- Alvarez ML. Isolation of urinary exosomes for RNA biomarker discovery using a simple, fast, and highly scalable method. Methods Mol Biol. 2014. 1182:145-70. PMID: 25055908.
- Sohel MM, et al. Exosomal and Non-Exosomal Transport of Extra-Cellular microRNAs in Follicular Fluid: Implications for Bovine Oocyte Developmental Competence. PLoS One. 2013 Nov 4. 8(11):e78505. PMCID: PMC3817212.
- Gu Y, et al. Lactation-Related MicroRNA Expression Profiles of Porcine Breast Milk Exosomes. PLoS ONE. 2012. 7(8): e43691. PMCID: PMC3427246.
Supporting Data
Supporting Data
Taking efficient exosome isolation to a whole new level of quality
ExoQuick PLUS and ExoQuick-TC PLUS provide efficient exosome isolation with reduced protein carry-over, resulting in isolated exosomes suitable for most sensitive downstream applications.
ExoQuick PLUS
FAQs
Resources
Citations
Related Products
Products
Catalog Number | Description | Size | Price | Quantity | Add to Cart | |||
---|---|---|---|---|---|---|---|---|
EQPL10TC-1 | ExoQuick-TC PLUS Exosome Purification Kit - Tissue Culture Media | 10 Reactions | $537 |
|
Overview
Overview
We have recently released our most advanced EV isolation system to-date—ExoQuick-TC ULTRA—unmatched combination of yield, purity, ease of use, and cost. Learn more.
Quick and efficient exosome isolation for sensitive applications
While the ExoQuick® family of reagents speed-up and simplify exosome isolation and are compatible with most downstream uses, some applications are especially sensitive to carry-over of non-exosomal proteins—applications such as mass spectrometry, Western blotting of low abundance markers, exosome labeling, and in vivo/ex vivo exosome delivery. Which is why SBI offers ExoQuick PLUS.
Less is more—ExoQuick PLUS and ExoQuick-TC PLUS for when you need an extra level of confidence:
- Better—delivers as much as 150-fold higher yields than ultracentrifugation-based methods
- Cleaner—dramatically reduces the amount of carry-over protein compared to other column- or precipitation-based kits, and even ultracentrifugation-based methods
- Powerful—detects biomarkers with as much as a 3-fold increase in sensitivity
- Fast—takes less than 10 minutes of hands-on-time after initial ExoQuick isolation
Building on our popular ExoQuick family of products, ExoQuick-TC PLUS delivers dramatically reduced albumin contamination in serum/plasma preparations compared to ultracentrifugation-based isolation methods, and considerably less carryover protein compared to other exosome isolation kits. Even better, isolation with the ExoQuick PLUS family of products results in much higher yields than isolation with ultracentrifugation—as much as 150-fold higher.
With a simple treatment of our ready-to-use, customized ExoQuick PLUS Microspheres (kits contain enough ExoQuick-TC and pre-packed Microspheres for 10 reactions*), you can obtain highly pure, intact exosomes suitable for a variety of protein-sensitive applications. Total hands-on time after ExoQuick-TC isolation is less than 10 minutes!
*For exosome isolation from serum or plasma, one reaction is defined as 250 µL of serum or plasma. For exosome isolation from tissue culture media, one reaction is defined as 5 mL of media.
Learn more about ExoQuick—click here.
Choose the right ExoQuick for your application:
Application | Product | Catalog # |
---|---|---|
Purest EV isolation | ExoQuick ULTRA and ExoQuick-TC ULTRA | EQULTRA-20A-1 EQULTRA-20TC-1 |
General purpose EV isolation | ExoQuick and ExoQuick-TC | EXOQ20A-1 EXOTC50A-1 |
EV isolation for pre-clinical/in vivo studies | ExoQuick-CG | EXOCG50A-1 |
EV isolation that removes contaminating lipoprotein particles from plasma or serum | ExoQuick-LP | EXOLP5A-1 |
EV isolation that includes a de-fibrinating plasma step prior to isolation | ExoQuick Plasma Prep with Thrombin | EXOQ5TM-1 |
References
How It Works
How It Works
High-throughput, quantitative exosome recovery
ExoQuick-TC PLUS can be used to purify exosomes from tissue culture media1, plus several biofluids, including saliva2, urine3, follicular fluid4, and breast milk5. With a simple workflow involving minimal hands-on time and low input sample volume requirements, ExoQuick-TC PLUS is an excellent option for researchers who need to purify multiple exosome samples and/or samples from small animal models or clinical research samples that will then be used in sensitive downstream applications.
To isolate exosomes from cell culture media, simply:
- Add an appropriate volume of ExoQuick-TC PLUS to as little as 100 µl sample
- Incubate for at least one hour at 4°C
- Pellet exosomes with a 30-minute low-speed spin (1500g)
- Resuspend pellet, add ExoQuick PLUS Microspheres, and incubate for 10 minutes at 4°C
- Remove microspheres with a 30-minute low-speed spin (1500g)
ExoQuick-TC PLUS-isolated exosomes can be found in the supernatant.
You can verify the presence of exosomes with a number of different methods, including Western blotting for general exosome markers (CD63, CD9, CD81, and HSP70), Nanoparticle Tracking Analysis (NTA), or EM (learn about different ways to detect exosomes and more in our Exosome Basics Guide).
REFERENCES
- Zhu L, et al. Novel method for extracting exosomes of hepatocellular carcinoma cells. World J Gastroenterol. 2014 June 7. 20(21): 6651-6657. PMCID: PMC4047354.
- Yang J, et al. Detection of Tumor Cell-Specific mRNA and Protein in Exosome-Like Microvesicles from Blood and Saliva. PLoS ONE. 2014. 9(11): e110641. PMCID: PMC 4232306.
- Alvarez ML. Isolation of urinary exosomes for RNA biomarker discovery using a simple, fast, and highly scalable method. Methods Mol Biol. 2014. 1182:145-70. PMID: 25055908.
- Sohel MM, et al. Exosomal and Non-Exosomal Transport of Extra-Cellular microRNAs in Follicular Fluid: Implications for Bovine Oocyte Developmental Competence. PLoS One. 2013 Nov 4. 8(11):e78505. PMCID: PMC3817212.
- Gu Y, et al. Lactation-Related MicroRNA Expression Profiles of Porcine Breast Milk Exosomes. PLoS ONE. 2012. 7(8): e43691. PMCID: PMC3427246.
Supporting Data
Supporting Data
Taking efficient exosome isolation to a whole new level of quality
ExoQuick PLUS and ExoQuick-TC PLUS provide efficient exosome isolation with reduced protein carry-over, resulting in isolated exosomes suitable for most sensitive downstream applications.
ExoQuick PLUS