ExoELISA-ULTRA Complete Kit (CD81 Detection)
- Sensitive—detect as little as 1 µg protein equivalent
- Fast—complete in less than 4-hours—no more overnight incubation
- Flexible—compatible with all major exosome isolation methods (e.g. ExoQuick, ultracentrifugation, ultrafiltration, and immunoaffinity capture) from human samples
- Quantitative—calibrated internal standards enable quantitation of exosomes carrying CD81
- Sample-saving—requires significantly less sample than our standard ExoELISA Kit, leaving more for other downstream applications
Products
Catalog Number | Description | Size | Price | Quantity | Add to Cart | |||
---|---|---|---|---|---|---|---|---|
EXEL-ULTRA-CD81-1 | ExoELISA-ULTRA Complete Kit (CD81 detection) | 96 Reactions | $673 |
|
Overview
Overview
Delivering ELISA-based exosome quantitation ULTRA fast
Improving on our popular ExoELISA Kits, the ExoELISA-ULTRA CD81 Kit increases the sensitivity of exosome detection—as low as 1 µg protein equivalent—while shortening the total assay time to only 4 hours.
Currently configured for detection of CD81, a common exosomal marker, ExoELISA-ULTRA CD81 is based on an ultra-sensitive, direct capture, colorimetric ELISA assay that is compatible with common biofluids. The ExoELISA-ULTRA CD81 Kit comes with an internal standard calibrated to exosomes from a range of biofluids. Calibration is achieved by NTA analysis and enables quantitation of exosomes carrying CD81 in your target samples. One ExoELISA-ULTRA CD81 Kit contains all of the necessary reagents (including assay plate) to perform up to 96 reactions.
- Sensitive—detect as little as 1 µg protein equivalent
- Fast—complete in less than 4-hours—no more overnight incubation
- Flexible—compatible with all major exosome isolation methods (e.g. ExoQuick, ultracentrifugation, ultrafiltration, and immunoaffinity capture) from human samples
- Quantitative—calibrated internal standards enable quantitation of exosomes carrying CD81
- Sample-saving—requires significantly less sample than our standard ExoELISA Kit, leaving more for other downstream applications
ExoELISA-ULTRA Complete Kits | EXOCET | FluoroCet | |
---|---|---|---|
Use | For fast and sensitive antibody-based quantitation of exosomes | For fast quantitation of extracellular vesicles with moderate sample input requirements | For the most sensitive quantitation of extracellular vesicles with very low sample input requirements |
Detection method | Antibody | Enzymatic | Enzymatic |
Quantitation chemistry | Enzymatic (HRP) | Colorimetric | Fluorescent |
Total protocol time | 4 hours (no overnight incubation) | 20 min | 60 min |
Input sample amount (protein equivalent) | 1 – 200 µg | 50 µg | <1 µg |
Learn More | ExoELISA-ULTRA CD63 ExoELISA-ULTRA CD81 ExoELISA-ULTRA CD9 ExoELISA-ULTRA GroEL | EXOCET | FluoroCet |
References
How It Works
Supporting Data
FAQs
Resources
Citations
Related Products
Products
Catalog Number | Description | Size | Price | Quantity | Add to Cart | |||
---|---|---|---|---|---|---|---|---|
EXEL-ULTRA-CD81-1 | ExoELISA-ULTRA Complete Kit (CD81 detection) | 96 Reactions | $673 |
|
Overview
Overview
Delivering ELISA-based exosome quantitation ULTRA fast
Improving on our popular ExoELISA Kits, the ExoELISA-ULTRA CD81 Kit increases the sensitivity of exosome detection—as low as 1 µg protein equivalent—while shortening the total assay time to only 4 hours.
Currently configured for detection of CD81, a common exosomal marker, ExoELISA-ULTRA CD81 is based on an ultra-sensitive, direct capture, colorimetric ELISA assay that is compatible with common biofluids. The ExoELISA-ULTRA CD81 Kit comes with an internal standard calibrated to exosomes from a range of biofluids. Calibration is achieved by NTA analysis and enables quantitation of exosomes carrying CD81 in your target samples. One ExoELISA-ULTRA CD81 Kit contains all of the necessary reagents (including assay plate) to perform up to 96 reactions.
- Sensitive—detect as little as 1 µg protein equivalent
- Fast—complete in less than 4-hours—no more overnight incubation
- Flexible—compatible with all major exosome isolation methods (e.g. ExoQuick, ultracentrifugation, ultrafiltration, and immunoaffinity capture) from human samples
- Quantitative—calibrated internal standards enable quantitation of exosomes carrying CD81
- Sample-saving—requires significantly less sample than our standard ExoELISA Kit, leaving more for other downstream applications
ExoELISA-ULTRA Complete Kits | EXOCET | FluoroCet | |
---|---|---|---|
Use | For fast and sensitive antibody-based quantitation of exosomes | For fast quantitation of extracellular vesicles with moderate sample input requirements | For the most sensitive quantitation of extracellular vesicles with very low sample input requirements |
Detection method | Antibody | Enzymatic | Enzymatic |
Quantitation chemistry | Enzymatic (HRP) | Colorimetric | Fluorescent |
Total protocol time | 4 hours (no overnight incubation) | 20 min | 60 min |
Input sample amount (protein equivalent) | 1 – 200 µg | 50 µg | <1 µg |
Learn More | ExoELISA-ULTRA CD63 ExoELISA-ULTRA CD81 ExoELISA-ULTRA CD9 ExoELISA-ULTRA GroEL | EXOCET | FluoroCet |